Fax 515-265-8794    800-362-2910     515-262-5900

Home | Sitemap | Contact Seneca |  Inventory | Tank Truck Info | Chassis | Catalogs

Purpose of Overfill Detection

 

To prevent a fuel spill should the loading process 

fail to stop before overfilling a tank compartment.

 

Overfill detection systems are required on all DOT 306/406

 

FloTech equipment meets the API standard and is compatible with other manufacture's equipment designed to meet API standards.

FloTech offers a limited two year warranty against defects of materials and workmanship.

 

CLICK HERE FOR COMPARISON REFERENCE CHART

    

FLOTECH OVERFILL PROTECTION

FT 202 TOP SENSOR
bullet2"NPT Thread
bulletExclusive elastomer prism seal for longer life (other use epoxy seals that can become brittle, crack, leak, and cloud optics
bulletDirect interchanges with Civacon # 1050 Sensor

SOCKETS
bulletDirect "Drop-in" replacement for similar Scully & Civacon products
bulletUnique set of "J-slots" and button contacts as specified in API 1004

FT204 RETAIN/OVERFILL MOINTOR
bulletMonitors up to 6 FT206 Bottom Retain Sensors for each compartment
bulletMonitors up to 6 FT202 Top sensors for each compartment
bulletDirect replacement for Civacon 3200 or 2

FT 206 RETAIN BOTTOM SENSOR
bullet1/2" NPT thread mounts to underside of "belly" of tank conpartment
bullet
Directly interchanges with Civacon #1000 Retain Sensor

SOCKETS
bulletHardcoat face plate reduces wear of "J" slots
bulletStainless steel hardware prevents corrosion
bulletDust cap provided
bulletAPI Compatable

2 WIRE THERMO-OPTIC PROBES & SENSORS
bulletdirect "drop-in" replacement for Scully & Civacon parts
bulletReplaces clasic Green or Silver T.P. Thermistor sensor for instant start & longer life
bulletFlotech has the exclusive elastomer prisom seal for longer service life

5 WIRE OPTIC PROBES & SENSORS
bulletdirect "drop-in" replacement for Scully & Civacon parts
bulletFlotech has the exclusive elastomer prisom seal for longer service life
bulletAPI Optic Compatible

THERMISTOR DUMMY
bullet5 channel electrical thermistor dummy
bulletinstant start in cold weather
bulletAPI thermistor compatible
bulletDirect "drop-in" replacement for Scully or Civacon parts

FT520 TESTER

Allows for easy, fast and economical way to check system

FT510 TESTER

Allows for easy, fast and economical way to check system

FT600 RACK CORD

Industry compatible for an easy to use, durable cord for loading racks

 

COMPARISON REFERENCE CHART

   

CLICK HERE TO ORDER FLOTECH PARTS

   
Flotech Civacon S description    
FT100 1300 21500/09209 Replacement probe, optic, 5 wire, 7" long    
FT100-12 1300s 08758/09214 Replacement probe, optic, 5 wire, 12" long    
FT101 1110 07894/09208 Sensor, optic, 5 wire, 2" NPT housing, 7" probe    
FT101-12 1110s 08698 Sensor, optic, 5 wire, 2" NPT housing with 12" probe    
FT150 1650 22389/09409 Replacement probe, Thermo-Optic, 2 wire, 7" long    
FT150-12 1650s 31483 Replacement probe, Thermo-Optic, 2 wire, 12" long    
FT151 1550 08501 Sensor, Thermo-Optic 2 wire, 2. NPT housing, 7" probe    
FT151-12 1550s 08700 Sensor, Thermo-Optic 2 wire, 2" NPT housing with 12" probe    
FT155 1900 08298/08542 Thermistor Dummy, 5 compartment    
FT201 1350   Replacement R/OM type, 2 wire, 7" top probe    
FT201-12 1350S   Replacement R/OM type, 2 wire, 12" top probe    
FT202 1050   Top Sensor R/OM type, with 2" NPT housing, 7" probe    
FT202-12     Top Sensor R/OM type, with 2" NPT housing, 12" probe    
FT205 1910   Terminator    
FT206 1000   Retain Sensor R/OM type, 1/2 NPT sensor    
Flotech Civacon Scully DESCRIPTION    
FT102 3150 08563 Replacement chassis, API compatible    
FT103 3100 08687 API compatible onboard monitor, w/housing    
FT203 3252   Replacement chassis, R/OM type onboard monitor    
FT204 3202   R/OM type onboard monitor, w/housing    
Flotech Civacon Scully DESCRIPTION    
FT300 4100 07974 API compatible optic socket with cap    
FT301 4400 07720 API compatible thermistor socket with cap    
FT302 4600 08116 API compatible float socket    
FT303 4200 07976 Optic Pattern with thermistor J slots, and cap    
FT304 4401 07716 Canadian/Euro thermistor socket with cap    
FT305 4500 07681 Thermistor socket, J560 type    
FT306 4300 08199 Optic socket, J560 type    
FT310 4110 21790 API Optic faceplate assembly with cap    
FT311 4410 20770 API Thermistor faceplate assembly with cap    
FT314   20768 Canadian/Euro thermistor replacement faceplate with cap    
FT320 4150 08575 Blue optic dust cap    
FT321 4450 08574 Green thermistor dust cap    
Flotech Civacon Scully DESCRIPTION    
FT1004 2004 08305 API compatible 4 compartment system    
FT1005 2005 08306 API compatible 5 compartment system    
FT2004 3024   R/OM type, 4 compartment system    
FT2005 3025   R/OM type, 5 compartment system    
FT2104 3034   R/OM type, 4 compartment system (top only)    
FT2105 3035   R/OM type, 5 compartment system (top only)    
Flotech Civacon Scully DESCRIPTION    
FT400 2100 22056 5 conductor cable 100'    
FT401 2310 27382 7 conductor cable 100'    
FT402 2510   20 strain relief fittings, 1/2 NPT    
FT403     30 strain relief fittings, 1/2 NPT    
FT510     Thermistor System Tester    
FT520     Optic System Tester    

 

 

Seneca Tank    5585 NE 16th Street    Des Moines, Iowa  50313

Please e- mail Seneca Tank webmaster with any questions or comments about this web site.